24 hr. Critical Incident Response Line 1-888-962-2100

FIRST RESPONDER SUPPORT TRAILER SYSTEM (FIRST)

Utility Trailer System offers first response agencies the ability to support such facilities as the TVI command shelter. The trailer is outfitted with a generator system and an environmental control unit for heating and air conditioning. As with the FIRST trailer system ample payload space is provided so that your TVI shelter can be transported as well.

 

Includes:
  • Electric Generator (Diesel Powered)
  • Environmental Control Unit (HVAC)
  • Portable Water Tank
  • Chem/Bio Air Filtration System
  • Scene Lighting
     
    Features Benefits
    Comprehensive On-Board Utilities
    Rapid Deployment of Total System
    Shelters Stored on Trailer
     
    Additional Info

    FIRST Trailer Specifications 

    Deck Dimensions                                 19' 9 5/116" L  x  8' 6" W  x  34" H

    Hitch Weight                                                        970 lbs

    Ball Size                                                 3" Pintle Ring

    G.V.W.R.                                                                9,000 lbs

    Axles (Tandem)                                                    14,000 lbs with EX-Lube

    Wheel Track                                                         7' 6"

    Brakes                                                                    Electric with Automatic Breakaway Actuator

    Tires                                                                       STS235/80R16 (D)

    Wheels                                                                  8 on 6.5

    Frame                                                                     C6 x 8.2 Steel

    Floor                                                                       11 Ga Diamond Plate

    Dual Safety Chain               

    Generator Specifications       

    Rated at 28kW,  Three Phase; 26kW, Single Phase Emergency  

    Rated at 27kW,  Three Phase; 25kW Single Phase Prime Power Application           

    Switchable Voltage                                              Single Phase: 120/240 Volts, 60 Hz, 1.0 Power Factor

                                                                                    Three Phase: 120/240 Volts, 60 Hz, 0.8 Power Factor

                                                                                    Three Phase: 277/480 Volts, 60hz, 0.8 Power Factor

    Engine                                                                    Deutz Diesel Model F4M 1011 F -  Four Cylinder, Oil, Cooled,

                                                                                    Naturally Aspirated, Operating at 1,800RPM, Includes Heavy Duty

                                                                                    Dry Type Air

    Cleaner and Critical Type Silencer [030/35 dB (A) ]      

                                                                                    Equipped with an Electric Voltage Regulator with +/- 1.5% Accuracy,

                                                                                    Class H Insulation

    Control Panel                                                        Key Start; metering of the following parameters: Oil Pressure,

                                                                                    Coolant temperature, Running Time, fuel Level, Voltage (+Selector

                                                                                    Switch), Current (+Selector Switch), frequency; automatic Shut

                                                                                    Temperature, Low Oil Pressure, Over Speed, Under Speed,

                                                                                    High/Low battery Voltage and Output; receptacle Panel

    Weather Sound Enclosure                 Unit installed in a Metallic Sound and Weather Proof Enclosure,

                                                                                    rated at 68.5 dB (A) at 23'

    Complete Assembly is mounted on a vibration isolators and on a full length steel sub base (32 Gal Single Wall, non UL Fuel Tank Incorporated) including, Battery Rack and Battery Cables.         

     

    ECU Specifications    

                    2 Light heads per Pole, 2 Extendable Poles     

                    Three Phase, 60Hz Motor. No relieve valve with pump, close coupled pump and motor only.

                    For a Flooded Suction Service of 20.5 GPM at 116' (50 PSI) with Water    

                    1500 CFM Auto-Adjusting, non bag in/bag out filtration system

    Triple elements filter design includes particulate pre-filter, higher capacity 99.99@ at .3 micron HEPA filter  and ChemPak  carbon adsorber filter

    Chemical and Biological Filtration

     

    Download Print Ready
    Data Sheet
    First Responder
     Isolation/Infection Control
     PAPR Respiratory Protection
     Decontamination Systems
     Decontamination Shelters
     Accessories
     Command and Control
     Law Enforcement Systems
     Trailer Systems
     Thermal
     Containment
     Generators
     Filter Plant
    PRODUCTS
     Decon
     Shelters
     Hospital/Surge
     Infection Control
     Respiratory
     Trailer Systems
     Generators
     Access
     Thermal
     Filters
    ISO 9001:2000 Certified
    Providing our customers with the highest quality products and services