FIRST RESPONDER SUPPORT TRAILER SYSTEM (FIRST)

Utility Trailer System offers first response agencies the ability to support such facilities as the TVI command shelter. The trailer is outfitted with a generator system and an environmental control unit for heating and air conditioning. As with the FIRST trailer system ample payload space is provided so that your TVI shelter can be transported as well.

 

Includes:
  • Electric Generator (Diesel Powered)
  • Environmental Control Unit (HVAC)
  • Portable Water Tank
  • Chem/Bio Air Filtration System
  • Scene Lighting
 
Features Benefits
Comprehensive On-Board Utilities
Rapid Deployment of Total System
Shelters Stored on Trailer
 
Additional Info

FIRST Trailer Specifications 

Deck Dimensions                                 19' 9 5/116" L  x  8' 6" W  x  34" H

Hitch Weight                                                        970 lbs

Ball Size                                                 3" Pintle Ring

G.V.W.R.                                                                9,000 lbs

Axles (Tandem)                                                    14,000 lbs with EX-Lube

Wheel Track                                                         7' 6"

Brakes                                                                    Electric with Automatic Breakaway Actuator

Tires                                                                       STS235/80R16 (D)

Wheels                                                                  8 on 6.5

Frame                                                                     C6 x 8.2 Steel

Floor                                                                       11 Ga Diamond Plate

Dual Safety Chain               

Generator Specifications       

Rated at 28kW,  Three Phase; 26kW, Single Phase Emergency  

Rated at 27kW,  Three Phase; 25kW Single Phase Prime Power Application           

Switchable Voltage                                              Single Phase: 120/240 Volts, 60 Hz, 1.0 Power Factor

                                                                                Three Phase: 120/240 Volts, 60 Hz, 0.8 Power Factor

                                                                                Three Phase: 277/480 Volts, 60hz, 0.8 Power Factor

Engine                                                                    Deutz Diesel Model F4M 1011 F -  Four Cylinder, Oil, Cooled,

                                                                                Naturally Aspirated, Operating at 1,800RPM, Includes Heavy Duty

                                                                                Dry Type Air

Cleaner and Critical Type Silencer [030/35 dB (A) ]      

                                                                                Equipped with an Electric Voltage Regulator with +/- 1.5% Accuracy,

                                                                                Class H Insulation

Control Panel                                                        Key Start; metering of the following parameters: Oil Pressure,

                                                                                Coolant temperature, Running Time, fuel Level, Voltage (+Selector

                                                                                Switch), Current (+Selector Switch), frequency; automatic Shut

                                                                                Temperature, Low Oil Pressure, Over Speed, Under Speed,

                                                                                High/Low battery Voltage and Output; receptacle Panel

Weather Sound Enclosure                 Unit installed in a Metallic Sound and Weather Proof Enclosure,

                                                                                rated at 68.5 dB (A) at 23'

Complete Assembly is mounted on a vibration isolators and on a full length steel sub base (32 Gal Single Wall, non UL Fuel Tank Incorporated) including, Battery Rack and Battery Cables.         

 

ECU Specifications    

                2 Light heads per Pole, 2 Extendable Poles     

                Three Phase, 60Hz Motor. No relieve valve with pump, close coupled pump and motor only.

                For a Flooded Suction Service of 20.5 GPM at 116' (50 PSI) with Water    

                1500 CFM Auto-Adjusting, non bag in/bag out filtration system

Triple elements filter design includes particulate pre-filter, higher capacity 99.99@ at .3 micron HEPA filter  and ChemPak  carbon adsorber filter

Chemical and Biological Filtration

 

Download Print Ready
Data Sheet
PRODUCTS
 Decon
 Shelters
 Hospital/Surge
 Infection Control
 Respiratory
 Trailer Systems
 Generators
 Access
 Thermal
 Filters
ISO 9001:2000 Certified